Main SP Tables-1
D146/D147/D148/D149/D150 2-100 System Maintenance Section
Do not change. No 8 position (middle shade) Transitions temperature of 1SRA3
201
Shading Position Temp:
12inch: Clear
ENG [0 to 250 / 0 / 1deg/step]
Do not change. Temperature threshold to return 12inch position to HP
202
Shading Position Temp: A3:
Clear
ENG [0 to 250 / 0 / 1deg/step]
Do not change. Temperature threshold to return A3 position to HP
203
Shading Position Temp: DLT:
Clear
ENG [0 to 250 / 0 / 1deg/step]
Do not change. Temperature threshold to return DLT position to HP
204
Shading Position Temp: B4:
Clear
ENG [0 to 250 / 0 / 1deg/step]
Do not change. Temperature threshold to return B4 position to HP
205
Shading Position Temp: LT:
Clear
ENG [0 to 250 / 0 / 1deg/step]
Do not change. Temperature threshold to return LT position to HP
206
Shading Position Temp: A4:
Clear
ENG [0 to 250 / 0 / 1deg/step]
Do not change. Temperature threshold to return A4 position to HP
207
Shading Position Temp: B5:
Clear
ENG [0 to 250 / 0 / 1deg/step]
Do not change. Temperature threshold to return B5 position to HP
208
Shading Position Temp: A5:
Clear
ENG [0 to 250 / 0 / 1deg/step]
Do not change. Temperature threshold to return A5 position to HP
209
Shading Position Temp: B6:
Clear
ENG [0 to 250 / 0 / 1deg/step]
Do not change. Temperature threshold to return A6 position to HP