Main SP Tables-1
System Maintenance Section 2-145 D146/D147/D148/D149/D150
SP Mode Tables
017
Electrical Cooling Fan Op
Start Time
*ENG [0 to 900 / 300 / 1sec/step]
Sets start operation time of electric system cooling fan.
018
Fan Op Sw Temp Thres *ENG [0.0 to 100.0 / 2.0 / 0.1deg/step]
Sets temperature threshold (diff. value between switching temp.) of when
switching each fan.
019
Paper Exit Cooling Fan
Control Off Mode Time
*ENG [0 to 60 / 10 / 1min./step]
Sets off mode time till start paper exit cooling fan.
020
Electrical Cooling Fan Control
Off Mode Time
*ENG [0 to 60 / 10 / 1min./step]
Sets off mode time till electric system cooling fan.