Main SP Tables-1
D146/D147/D148/D149/D150 2-144 System Maintenance Section
007
Fusing Exit Fan Op Sw Temp *ENG [0.0 to 100.0 / 0.0/ 0.1deg/step]
Sets temperature threshold for when switching operation of fusing exhaust heat
fan.
009
Ozone Fan Low Speed Op Sw
Temp
*ENG [0.0 to 100.0 / 35.0 / 0.1deg/step]
Sets temperature threshold for when switching to low speed operation of fusing
exhaust heat fan.
010
Ozone Fan Middle Speed Op
Sw Temp
*ENG [0.0 to 100.0 / 37.0 / 0.1deg/step]
Sets temperature threshold for when switching to middle speed operation of
fusing exhaust heat fan.
011
Ozone Fan High Speed Op
Sw Temp
*ENG [0.0 to 100.0 / 40.0 / 0.1deg/step]
Sets temperature threshold for when switching to high speed operation of fusing
exhaust heat fan.
012
Ozone Fan Low Noise Op
DUTY
*ENG [0 to 100 / 20 / 1%/step]
Sets working duty when running ozone fan quiet.
013
Ozone Fan Low Speed Op
DUTY
*ENG [0 to 100 / 30 / 1%/step]
Sets working duty when running ozone fan low speed..
014
Ozone Fan Middle Speed Op
DUTY
*ENG [0 to 100 / 40 / 1%/step]
Sets working duty when running ozone fan middle speed.
015
Ozone Fan High Speed Op
DUTY
*ENG [0 to 100 / 40 / 1%/step]
Sets working duty when running ozone fan high speed.
016
Paper Exit Cooling Fan Op
Start Time
*ENG [0 to 900 / 300 / 1sec/step]
Sets start operation time of paper exit cooling fan.