Main SP Tables-1
System Maintenance Section 2-143 D146/D147/D148/D149/D150
1953 [Extra Fan Control]
001
Extra Fan Cooling State *ENG
[0 or 1 / 0 / 1/step]
0: Disable
1: Enable
Displays current fan extend operation
002
Execution Temp. Threshold
*ENG
[0.0 to 100.0 / D146:42.0,
D147:42.0, D148:39.0, D149:39.0,
D150:39.0 / 0.1deg/step]
Sets judge time for to start fan extend operation.
003
Cancellation Temp. Threshold *ENG [0.0 to 100.0 / 2.0 / 0.1deg/step]
Sets temperature threshold (diff. value between fan extend start temp.) of when
ending fan extend operation.
004
Extra Fan Operation ON/OFF
Setting
*ENG
[0 or 1 / 1 / 1/step]
0: disable
1: enable
Sets enable/disable fan extend operation.
1955 [Fan Control]
003
Dev Cooling Fan A Op Sw
Temp
*ENG [0.0 to 100.0 / 1.0 / 0.1deg/step]
Sets temperature threshold for when switching operation of imaging cooling fan
A.
004
Dev Cooling Fan B Op Sw
Temp
*ENG [0.0 to 100.0 / 36.0 / 0.1deg/step]
Sets temperature threshold for when switching operation of imaging cooling fan
B.
006
Paper Exit Cooling Fan Low
Temp Op Sw Tem p
*ENG [0.0 to 100.0 / 12.0 / 0.1deg/step]
Sets temperature threshold for when switching operation during low temp. of
paper exit cooling fan.