Main SP Tables-2-1
D146/D147/D148/D149/D150 2-154 System Maintenance Section
002 Environmental Target: C *ENG 0.91, D148: 1.23, D149: 1.68,
D150: 1.68 / 0.01mA/step]
003 Environmental Target: M *ENG
004 Environmental Target: Y *ENG
2011
[Charge AC Current: HH]
AC ampere target value when Electrify AC.
001 Environmental Target: Bk *ENG
[0.00 to 3.00 / D146: 0.92, D147:
0.92, D148: 1.30, D149: 1.73,
D150: 1.73 / 0.01mA/step]
002 Environmental Target: C *ENG
003 Environmental Target: M *ENG
004 Environmental Target: Y *ENG
2012 [Charge Output Control]
001
AC Voltage *ENG [0 or 1 / 0 / 1/step]
0: Set to environment correction value used when FB .
1: Electrify AC voltage of SP: Set to fixed setting value.
2013 [Environmental Correction: PCU]
001
Current Environmental FC :
Display
*ENG [0 to 0 / 0 / 1/step]
Environment class divided based on the temperature / humidity sensor
information when controlling Electrify AC of latest main & subs FC mode.
002
Forced Setting *ENG [0 to 5 / 0 / 1/step]
0: Detect with temperature / humidity sensor.
1 to 5: Force setting environment.
003
Absolute Humidity: Threshold
1
*ENG
[0.00 to 100.00 / 3.00 /
0.01g/m^3/step]
Threshold of LL environment and ML environment.