Main SP Tables-2-1
System Maintenance Section 2-155 D146/D147/D148/D149/D150
SP Mode Tables
004
Absolute Humidity: Threshold
2
*ENG
[0.00 to 100.00 / 8.00 /
0.01g/m^3/step]
Threshold of ML environment and MM environment.
005
Absolute Humidity: Threshold
3
*ENG
[0.00 to 100.00 / 15.00 /
0.01g/m^3/step]
Threshold of MM environment and MH environment.
006
Absolute Humidity: Threshold
4
*ENG
[0.00 to 100.00 / 22.00 /
0.01g/m^3/step]
Threshold of MH environment and HH environment.
007
Temp FC: Display *ENG [0 to 100 / 0 / 1deg/step]
Temperature detected with temperature / humidity sensor when controlling
Electrify AC of latest main and subs FC mode.
008
Relative Humidity FC :
Display
*ENG [0 to 100 / 0 / 1%RH/step]
Relative temperature detected with temperature / humidity sensor when
controlling Electrify AC of latest main and subs FC mode.
009
Absolute Humidity FC :
Display
*ENG
[0.00 to 100.00 / 0.00 /
0.01g/m^3/step]
Absolute temperature detected with temperature / humidity sensor when
controlling Electrify AC of latest main and subs FC mode.
010
Environmental Bk: Display *ENG [0 to 0 / 0 / 1/step]
Environment class divided based on the temperature / humidity sensor
information when controlling Electrify AC of latest main & subs monochrome Bk
mode.
011
Temp Bk.: Display *ENG [0 to 100 / 0 / 1deg/step]
Temperature detected by the temperature / humidity sensor when controlling
Electrify AC of latest main & subs monochrome Bk mode.