Main SP Tables-2-1
System Maintenance Section 2-157 D146/D147/D148/D149/D150
007
Temp Threshold M *ENG [0 to 99 / 10 / 1deg/step]
Temperature variation threshold for deciding of executing main control.
0: Execute every time when set.
008
RH Threshold M *ENG [0 to 99 / 50 / 1%RH/step]
Relative humidity variation threshold for deciding of executing main adjust.
0: Execute every time.
009
AH Threshold M *ENG [0 to 99 / 6 / 1g/m^3/step]
Relative humidity variation threshold for deciding of executing main adjust.
0: Execute every time.
010
Temp Threshold S *ENG [0.0 to 20.0 / 1.0 / 0.1deg]
Temperature variation threshold to do sub adjust.
0: Do every time
011
RH Threshold S *ENG [0 to 50 / 5 / 1%RH/step]
Relative humidity variation threshold to do sub adjust.
0: Do every time
012
AH Threshold S *ENG [0.0 to 20.0 / 1.0 / 0.1g/m^3/step]
Absolute humidity variation threshold to do sub adjust.
0: Do every time if conditions match.
013
Non-use Time *ENG [0 to 1440 / 360 / 10min./step]
Threshold of time stopping photoreceptor continuously for main adjust.
0: Do not.
014
AC Current Error Detection *ENG [0 or 1 / 0 / 1/step]
Flag to decide whether to adjust AC when SC491 is detected.