Main SP Tables-2-1
D146/D147/D148/D149/D150 2-158 System Maintenance Section
2015 [Charge AC Adj: Result]
001
Bk *ENG [0 to 9 / 0 / 1/step]
Result of AC adjust control for Bk (main / sub common)
002
C *ENG [0 to 9 / 0 / 1/step]
Result of AC adjust control for C (main / sub common)
003
M *ENG [0 to 9 / 0 / 1/step]
Result of AC adjust control for M (main / sub common)
004
Y *ENG [0 to 9 / 0 / 1/step]
Result of AC adjust control for Y (main / sub common)
2020 [Background Pot Correction Set]
001
Temperature *ENG [0 to 19 / 15 / 1deg/step]
Temperature threshold for calculating Electrify roller fatigue.
002
Absolute Humidity *ENG [0 to 99 / 6 / 1g/m^3/step]
Absolute humidity threshold for calculating Electrify roller fatigue.
003
Print Page Counter *ENG [0 to 999 / 0 / 1page/step]
Printing counter for multi-step correction.
004
Print Pages Threshold *ENG [0 to 999 / 10 / 1page/step]
Printing pages threshold when Multi-step correction.
005
Temp Thresh *ENG [20 to 99 / 20 / 1deg/step]
Temperature threshold 2 for calculating Electrify roller fatigue.
011
Coefficient a: K *ENG [0.00 to 1.00 / 0.06 / 0.01/step]
Coefficient a, K for calculating Electrify roller fatigue.
012
Coefficient a: C *ENG [0.00 to 1.00 / 0.06 / 0.01/step]
Coefficient a, C for calculating Electrify roller fatigue.