Main SP Tables-2-1
D146/D147/D148/D149/D150 2-180 System Maintenance Section
2144 [TM/ID Sensor Check Result]
005
Maximum 2: Front *ENG [0.00 to 5.50 / 0.00 / 0.01V/step]
Saves/ refreshes this SP with the max. value of all sampling data form TMP
sensor [Front] detecting result data by image transfer belt / TMP sensor check
mode result.
006
Maximum 2: Center *ENG [0.00 to 5.50 / 0.00 / 0.01V/step]
Saves/ refreshes this SP with the max. value of all sampling data form TMP
sensor [Center] detecting result data by image transfer belt / TMP sensor check
mode result.
007
Maximum 2: Rear *ENG [0.00 to 5.50 / 0.00 / 0.01V/step]
Saves/ refreshes this SP with the max. value of all sampling data form TMP
sensor [Rear] detecting result data by image transfer belt / TMP sensor check
mode result.
2145 [TM/ID Sensor Check Result]
005
Minimum 2: Front *ENG [0.00 to 5.50 / 0.00 / 0.01V/step]
Saves/ refreshes this SP with the min. value of all sampling data form TMP
sensor [Front] detecting result data by image transfer belt / TMP sensor check
mode result.
006
Minimum 2: Center *ENG [0.00 to 5.50 / 0.00 / 0.01V/step]
Saves/ refreshes this SP with the min. value of all sampling data form TMP
sensor [Center] detecting result data by image transfer belt / TMP sensor check
mode result.
007
Minimum 2: Rear *ENG [0.00 to 5.50 / 0.00 / 0.01V/step]
Saves/ refreshes this SP with the min. value of all sampling data form TMP
sensor [Rear] detecting result data by image transfer belt / TMP sensor check
mode result.