Main SP Tables-2-1
D146/D147/D148/D149/D150 2-194 System Maintenance Section
005
Page: Interrupt: FC *ENG [0 to 999 / 200 / 1page/step]
Condition threshold to auto execute MUSIC or not based on last printed sheets
from MUSIC during printing in Color mode.
006
Page: Stand-By: BW *ENG [0 to 999 / 100 / 1page/step]
Condition threshold to auto execute MUSIC or not based on last printed
B&W+Color sheets from MUSIC during stand-by.
007
Page: Stand-By: FC *ENG [0 to 999 / 100 / 1page/step]
Condition threshold to auto execute MUSIC or not based on last printed Color
sheets from MUSIC during stand-by.
008
Temp. *ENG [0 to 100 / 5 / 1deg/step]
Condition threshold to auto execute MUSIC or not based on the variation of
environment temperature (Temperature and humidity sensor) since last MUSIC.
009
Time *ENG [1 to 1440 / 300 / 1minute/step]
Condition threshold to auto execute MUSIC on recover from energy save mode
/ Power on or not based on the elapsed time since last MUSIC.
010 Magnification *ENG [0.00 to 1.00 / 0.10 / 0.01%/step]
011
Temp. 2 *ENG [0 to 100 / 5 / 1deg/step]
Condition threshold (Threshold revel: Mid.) to auto execute MUSIC or not
based on the variation of internal temperature (drum temp. sensor) since last
MUSIC.
012 Time 2 *ENG [1 to 9999 / 600 / 1minute/step]
013
Temp. 3 *ENG [0 to 100 / 10 / 1deg/step]
Condition threshold (Threshold revel: Hi.) to auto execute MUSIC or not based
on the variation of internal temperature (drum temp. sensor) since last MUSIC.
016
Page: Power ON:BW+FC *ENG [0 to 999 / 200 / 1page/step]
Condition threshold to auto execute MUSIC on recover from energy save mode
/ Power on or not based sheets printed during electrification.