Main SP Tables-2-1
D146/D147/D148/D149/D150 2-196 System Maintenance Section
011
Error Result: M *ENG [0 to 9 / 0 / 1/step]
Saves / Refreshes this SP with the Magenta result among the MUSIC execution
result.
012
Error Result: Y *ENG [0 to 9 / 0 / 1/step]
Saves / Refreshes this SP with the yellow result among the MUSIC execution
result.
013
Error Result: K *ENG [0 to 9 / 0 / 1/step]
Saves / Refreshes this SP with the Black result among the MUSIC execution
result.
014
Temperature 2 *ENG [-10 to 100 / 0 / 1deg/step]
Saves / Refreshes this SP with the internal temperature (drum temp. sensor) of
last MUSIC.
2195 [Realtime MUSIC Condition Set]
001
ON/OFF *ENG
[0 or 1 / 1 / 1/step]
0: OFF
1: ON
Sets whether to have real time MUSIC ON (1) or OFF (0).
002
Page: Interrupt: BW+FC *ENG [0 to 999 / 50 / 1page/step]
Condition threshold to auto execute real time MUSIC based on the sheets
printed with last MUSIC during printing in B&W+Color.
003
Page: Interrupt: FC *ENG [0 to 999 / 50 / 1page/step]
Condition threshold to auto execute real time MUSIC based on the sheets
printed with last MUSIC during printing in Color.
004
Temperature 4 *ENG [0 to 100 / 1 / 1deg/step]
Condition threshold (Threshold revel: Mid.) to auto execute real time MUSIC or
not based on the variation of internal temperature (drum temp. sensor) since
last MUSIC.