Main SP Tables-2-1
System Maintenance Section 2-197 D146/D147/D148/D149/D150
005
Temperature 5 *ENG [0 to 100 / 1 / 1deg/step]
Condition threshold (Threshold revel: Hi.) to auto execute real time MUSIC or
not based on the variation of internal temperature (drum temp. sensor) since
last MUSIC.
2197 [MUSIC Start Time]
001
MUSIC Start Time (EDT) *ENG [10 to 40 / 20 / 10ms/step]
Sets margin time for starting scan to set starting position of scan MUSIC pattern
accurately.
002
TM Sensor Position *ENG [50.0 to 500.0 / 165.0 / 0.1mm/step]
Sets physical distance information of TMP Sensor to set MUSIC pattern
scanning start position accurately.
2220
[Skew Origin Set]
-
001
M: Skew Motor ENG [0 or 1 / 0 / -]
M: skew original setting.
002
C: Skew Motor ENG [0 or 1 / 0 / -]
C: skew original setting.
003
Y: Skew Motor ENG [0 or 1 / 0 / -]
Y: skew original setting.