Main SP Tables-2-1
D146/D147/D148/D149/D150 2-198 System Maintenance Section
2221
[LD Power: Fixed]
Decides output setting value as the value set to this SP when not controlling
Process control.
001 K *ENG
[0 to 200 / 100 / 1%/step]
002 C *ENG
003 M *ENG
004 Y *ENG
2229 [Develop DC Vias]
001
Standard Speed: Bk *ENG [0 to 800 / 550 / 1-V/step]
Refers to develop bias set to this SP when electric potential control with
Process control is not set. (Std. speed: Bk)
002
Standard Speed: C *ENG [0 to 800 / 550 / 1-V/step]
Refers to develop bias set to this SP when electric potential control with
Process control is not set. (Std. speed: C)
003
Standard Speed: M *ENG [0 to 800 / 550 / 1-V/step]
Refers to develop bias set to this SP when electric potential control with
Process control is not set. (Std. speed: M)
004
Standard Speed: Y *ENG [0 to 800 / 550 / 1-V/step]
Refers to develop bias set to this SP when electric potential control with
Process control is not set. (Std. speed: Y)
005
Middle Speed Bk *ENG [0 to 800 / 550 / 1-V/step]
Refers to develop bias set to this SP when electric potential control with
Process control is not set.
006
Middle Speed C *ENG [0 to 800 / 550 / 1-V/step]
Refers to develop bias set to this SP when electric potential control with
Process control is not set.