Air-cooled Motors
The MagneMover LITE air-cooled motors are designed to allow a continuous flow of clean,
dry air to provide additional cooling. These motors can be run as normal MM LITE motors by
installing the supplied 3/8 in BSPP plugs in the port locations. See MagneMover LITE G4
Motors on page 144 for the mechanical drawings.
Figure 4-66: Air-cooled Motor Pneumatic Connections
Air Cooling
A1: Supply air per ANSI 7.0.01-1996, Quality Standard for Instrument Air. Do not exceed
1.0 psig [6.9 kPa] inlet pressure or 4.0 scfm [113 L/min] inlet flow.
A2: Exhaust to atmosphere.
NOTE: Any hose connected to the A2 port generates a backpressure, which can limit
the cfm capability to satisfy the 1 psi specification.
Pressurizing
A1: Supply air per ANSI 7.0.01-1996, Quality Standard for Instrument Air. Do not exceed
1.0 psig [6.9 kPa] inlet pressure.
A2: Plugged.
Table 4-38: Air-cooled Motor Pneumatic Connectors
Label Description Connector Type
A1 Air In 12 mm OD one-touch fitting, 10 mm hex
A2 Air Out 12 mm OD one-touch fitting, 10 mm hex