Specifications and Site Requirements
Pneumatic Specifications
MagneMover LITE User Manual 227
Rockwell Automation Publication MMI-UM002F-EN-P - October 2022
Pneumatic Specifications
Air-cooled Motors
The MagneMover LITE air-cooled motors are designed to allow a continuous flow of clean,
dry air to provide additional cooling. These motors can be run as normal MM LITE motors by
installing the supplied 3/8 in BSPP plugs in the port locations. See MagneMover LITE G4
Motors on page 144 for the mechanical drawings.
Figure 4-66: Air-cooled Motor Pneumatic Connections
Air Cooling
A1: Supply air per ANSI 7.0.01-1996, Quality Standard for Instrument Air. Do not exceed
1.0 psig [6.9 kPa] inlet pressure or 4.0 scfm [113 L/min] inlet flow.
A2: Exhaust to atmosphere.
NOTE: Any hose connected to the A2 port generates a backpressure, which can limit
the cfm capability to satisfy the 1 psi specification.
Pressurizing
A1: Supply air per ANSI 7.0.01-1996, Quality Standard for Instrument Air. Do not exceed
1.0 psig [6.9 kPa] inlet pressure.
A2: Plugged.
Table 4-38: Air-cooled Motor Pneumatic Connectors
Label Description Connector Type
A1 Air In 12 mm OD one-touch fitting, 10 mm hex
A2 Air Out 12 mm OD one-touch fitting, 10 mm hex
In Out

Table of Contents

Other manuals for Rockwell Automation MagneMotion MagneMover LITE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation MagneMotion MagneMover LITE and is the answer not in the manual?

Rockwell Automation MagneMotion MagneMover LITE Specifications

General IconGeneral
BrandRockwell Automation
ModelMagneMotion MagneMover LITE
CategoryAccessories
LanguageEnglish

Related product manuals