Installation
Transport System Installation
MagneMover LITE User Manual 241
Rockwell Automation Publication MMI-UM002F-EN-P - October 2022
Transport System Installation
The MagneMover LITE transport system must be properly located within the facility so that
other equipment can interface to it as required. The location must also make sure that there is
adequate space for service access and for proper operation. Make sure that installation of the
MagneMover LITE components provides access to items required for service after installa-
tion, such as connection panels. Once properly located, the MagneMover LITE transport sys-
tem must be leveled and secured to the floor or other rigid mounting points to help prevent
any movement.
Installing Hardware
These hardware installation procedures assume use of the MagneMover LITE stand system to
support the motors and switches.
To install the motors and switches on user-supplied supports, make sure that the supports are
properly prepared to receive the motors and switches (see Mechanical Specifications on
page 148). Install the motors and switches (see Mounting Motors and Switches on page 256)
and make any adjustment necessary to account for the custom supports.
NOTE: Any bolts with plastic caps have been pre-tightened at the factory to the appropriate
torque specification and do not need to be tightened during installation.
When performing any of the following procedures, adhere to and follow all safety
warnings and instructions.
Required Tools and Materials
Metric Hex wrench set.
Torque wrench (0.9…26 N•m [8…230 in•lb] range) with metric and Torx bits.
Screwdriver, Small flat blade.
Screwdriver, Phillips.
12” Machinist Square.
Laser level, rotary.
Digital Multimeter.
Loctite 243, Thread locker, Anaerobic Adhesive, Blue.
Loctite 290, Thread locker, Wicking Grade, Green (precision rail option only).
Open-end wrench, 13 mm, thin (precision rail option only).
Ratcheting Hex wrenches; 10 mm, 13 mm, 14 mm, 17 mm.
000-0616-00 – Motor Alignment Fixture, ML.

Table of Contents

Other manuals for Rockwell Automation MagneMotion MagneMover LITE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation MagneMotion MagneMover LITE and is the answer not in the manual?

Rockwell Automation MagneMotion MagneMover LITE Specifications

General IconGeneral
BrandRockwell Automation
ModelMagneMotion MagneMover LITE
CategoryAccessories
LanguageEnglish

Related product manuals