Maintenance
Preventive Maintenance
MagneMover LITE User Manual 355
Rockwell Automation Publication MMI-UM002F-EN-P - October 2022
Procedure
1. Remove the wheeled puck from the MagneMover LITE transport system (see Replace
Pucks on page 399).
2. Wear gloves and clean the rolling surface of all wheels with clean cotton tipped swabs
slightly dampened with Isopropyl alcohol. Run the swabs over the wheels in a
back-and-forth motion in the direction of travel (see Figure 7-3).
NOTE: Squeezing the swab does not cause any alcohol to drip.
Figure 7-3: Wheeled Puck Cleaning
3. Wear gloves and clean external puck surfaces with a clean microfiber cloth slightly
dampened with Isopropyl alcohol. Run the cloth over the surfaces in the direction of
travel (see Figure 7-3).
NOTE: Squeezing the cloth does not cause any alcohol to drip.
4. Wear gloves and dry all cleaned puck surfaces with a clean, dry, cotton tipped swab,
and a clean dry microfiber cloth.
5. Replace the puck on the MM LITE transport system (see Replace Pucks on page 399).
Puck Body
Magnet Array
Lateral Guide
Wheels
Suspension
Wheels
Direction of Travel