Maintenance
Preventive Maintenance
366 MagneMotion
Rockwell Automation Publication MMI-UM002F-EN-P - October 2022
Refill the Lubrication Pump Reservoir for Precision Rail Systems
The lubricant cartridge attached to the pump must be replaced with a new perma STAR LC
cartridge that is filled with 68 viscosity EP mineral oil once it is emptied. A basic overview of
the procedure is provided, see the manufacturers documentation for detailed information.
NOTE: The lubrication system only lubricates the running surfaces of the rails, to lubricate
the entire rail see Manually Lubricate the Precision Rails on page 362.
The frequency of lubrication depends on the distance traveled.
Required Tools and Equipment
perma STAR LC cartridge filled with 68 viscosity EP mineral oil (Kluber 4
UH1-68N).
Procedure
1. Turn off lubrication pump.
2. Unscrew the empty Lubricant Cartridge (LC) and dispose of properly.
3. Screw on the new Lubricant Cartridge.
4. Return the pump to service.

Table of Contents

Other manuals for Rockwell Automation MagneMotion MagneMover LITE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rockwell Automation MagneMotion MagneMover LITE and is the answer not in the manual?

Rockwell Automation MagneMotion MagneMover LITE Specifications

General IconGeneral
BrandRockwell Automation
ModelMagneMotion MagneMover LITE
CategoryAccessories
LanguageEnglish

Related product manuals