Maintenance
Preventive Maintenance
MagneMover LITE User Manual 359
Rockwell Automation Publication MMI-UM002F-EN-P - October 2022
Cable Connection Inspection
1. Stop all motion on the sections of the MM LITE transport system to be inspected.
2. Verify that all cable connectors are fully seated and screws/locks are secured to
achieve good continuity.
3. Inspect all cables for restricting bend radii, excessive tension, or physical damage.
4. Return the MM LITE transport system to normal operation.
Hardware Inspection
1. Stop all motion on the sections of the MM LITE transport system to be inspected.
2. Turn off all MM LITE transport system components with accessible power controls.
3. Make sure that all motor stand hardware is secure.
4. Make sure that all motor mounting hardware is secure.
5. Make sure that all guideway mounting hardware is secure.
6. Make sure that all vehicle grounding materials (for example, static brushes) are secure
and functioning properly.
7. Make sure that all vehicle hardware, especially the hardware that holds the magnet
array, is secure.
8. Make sure that the vehicle gap (distance between the magnet array on the vehicle and
the motor) is within tolerance for all vehicles on all motors.
9. Return the MM LITE transport system to normal operation.
Transfer Log Files
Review the log files for each node controller and the HLC periodically to look for unexpected
messages.
Log files can be transferred from the node controller or SysLog server to a network server so
they can be archived or e-mailed to Technical Support, see the Node Controller Interface User
Manual, MMI-UM001.