Page #279 background imageLoading...
Page #279 background image
Installation
Transport System Installation
MagneMover LITE User Manual 279
Rockwell Automation Publication MMI-UM002F-EN-P - October 2022
Curved Motors
Figure 5-26: Installing Curved Motor Cable Chase Covers
1. Locate an inner cover against the bracket on the inside of the curve.
2. Install two M5 x 8 mm screws to secure the cover.
3. Locate an outer curve cover against the motor mount on the outside of the curve.
4. Install two M5 x 8 mm screws to secure the cover.
5. Tighten the four M5 screws to 1.6 N•m [14 in•lb] with a Phillips bit.
Outer Cover
Inner Cover
M5 Screw
(4X)

Table of Contents