Maintenance
Repair
MagneMover LITE User Manual 415
Rockwell Automation Publication MMI-UM002F-EN-P - October 2022
G. Locate the new lateral guide wheels and secure using the new M4 screws with
Dri-Loc and tighten to 0.9 N•m [8 in•lb].
The Loctite must cure for 2 hours at 22° C [72° F] before using the puck.
H. Verify that the wheel and axle areas for the two septum wheels are clean. Clean
if necessary.
I. Flip the puck body over and locate it on the magnet array.
J. Insert the new septum wheels into place in line with the threaded standoffs on
the magnet array.
K. Secure the puck body to the magnet array with the new M4 x 23.5 mm shoul-
der screws with Dri-Loc and tighten to 1.4 N•m [12 in•lb].
3. Replace the puck on the transport system (see Replace Pucks on page 399).