Maintenance
Repair
456 MagneMotion
Rockwell Automation Publication MMI-UM002F-EN-P - October 2022
1. Stop all motion on the path where the precision locator stand z-datums is located.
2. Remove the M4 screws that secure the z-datums to the inner and outer supports as
shown in Figure 7-51 and remove the z-datums.
3. Clean the z-datum mounting surfaces of the stand with Isopropyl alcohol to remove
any debris.
4. Install the new z-datum using M4 screws with Loctite 243 and tighten to 5 in-lbs as
shown in Figure 7-51.
The Loctite must cure for 2 hours at 22° C [72° F] before using the transport system.
5. Return the MM LITE transport system to normal operation.