7 Basic Functions for Scan Head and Laser Control
143
innovators for industry
Notes on Loading a Scaling Function
The command load_position_control loads a table
for the scaling function Scale(Position) from an ASCII
text file. The text file can contain one or more tables.
Each table can contain up to 50 data points
(Position Scale(Position)) for various positions. The
RTC
®
5 determines the scaling function
Scale(Position) from this data by linear interpolation.
The following rules apply for these tables:
Each table must start with the instruction
(Caption)
[
PositionCtrlTable
<No>]
where
<No>
must be replaced by a nonnegative
integer which denotes the table number.
If the table contains multiple
[PositionCtrlTable<No>]
entries with the same
<No>
, then only the instructions after the first
entry will be used; instructions that follow further
entries will be ignored. Only instructions up to the
next ’[’ character (that is not preceded by a
semicolon) are used.
Each data point (Position Scale(Position)) is
described by two instructions:
Position<n> = <Value>
Scale<n> = <Value>
where
<n>
must be replaced by an integer
(1
<n>
50) which denotes the number of the
data point. The values
<Value>
can be specified as
(unsigned) floating point numbers. Use the
period
(.)
as the decimal separator.
If the table contains multiple data points with the
same Index
<n>
, then the most recently read one
will be used and the previous ones ignored.
If the table contains multiple data points with the
same position value Position, then the data point
with the largest Index
<n>
will be used and the
others ignored. Equality is checked to within
±0.01.
The position value is specified radially as the
distance between the to-be-marked point and the
coordinate midpoint (= (x
2
+ y
2
)
1/2
) as a percent
value (percent of half the image-field side length).
Example: (X
max
|0) corresponds to 100%,
(X
max
|Y
max
) corresponds to 2
1/2
·100%
(with X
max
,Y
max
= 2
19
or 2
15
in RTC
®
4
compatibility mode)
•For
<Value>
, the following ranges apply:
0.0 Position 150.0 and
0.0 Scale(Position) 4.0.
(Though the RTC
®
5 uses the scaling function only
for the range 0.0 Position 141.42, the inter-
polation also takes into account values in the
range 141.42 Position 150.0)
Each instruction must be in a separate line.
Spaces and tabs in a line (e.g. between ’
=
’ and
<Value>
) are ignored.
Empty lines are ignored.
Data points with invalid values are ignored.
The data point of a particular index
<n>
is ignored
if the corresponding
Position<n>
and/or
Scale<n>
definition is missing.
The semicolon ’;’ can be used for comments. All
characters in a line following a semicolon are
ignored.
The instructions for data points in the table can
be ordered as desired.
Indices for data point pairs in the table can be
selected as desired within the range [1…50] (the
table will then be automatically sorted by
ascending position values).
If the table contains no valid data point, the
command load_position_control will have no
effect (return value 1 or 13).
If there is no entry for Position = 0.0, then an
entry with
Scale
=Min(
Scale<i>
) will be
inserted (the smallest allowed value defined in
the table will be used for lower positions values).
Likewise for Position = 150.0 with
Max(
Scale<i>
).
If the selected text file only contains a single valid
data point with
Scale<n> = S
, then (for the entire
position range) the scaling function
Scale(Position)
=S
will be loaded with the effect
that no position-dependent correction will be
executed. A 100% value set with
set_auto_laser_control (
Value
parameter) will
be multiplied by
S
. For
S
= 1.0, position-
dependent correction will therefore be fully
switched off. Alternatively, this can also be
achieved with
Name
=0 in
load_position_control.