10 Commands And Functions
447
innovators for industry
Comments
Note that half the period length must be specified for
HalfPeriod
(see figure 48 on
page 131 and figure 49 on page 134).
If
HalfPeriod
= 0 and/or
PulseLength1
= 0, no laser signals will be outputted.
If the softstart mode is used (see page 135),
HalfPeriod
should not be smaller than 104
(this is not automatically checked). This value corresponds to a laser pulse frequency of
approx. 308 kHz.
•If
PulseLength1
is larger than the output period (2 ·
HalfPeriod
), the laser will be
permanently on.
The time base setting applies only for the parameters of this command.
•For RTC
®
4 compatibility mode, SCANLAB generally recommends setting the time base
to 8 MHz. In this mode, a time base of 1 MHz should only be chosen if necessary.
Refer to chapter 7.4 "Laser Control", page 128, for details.
•In RTC
®
5 mode, the command set_laser_timing is identical to set_laser_pulses.
The signal level is defined via set_laser_control.
In laser mode 4 and laser mode 6, the time base for signals LASER1 and LASER2 is inde-
pendent of
TimeBase
and always 1/64 µs (in RTC
®
5 mode) or 1/8 µs (in RTC
®
4 compat-
ibility mode).
RTC
®
4
RTC
®
5 With the RTC
®
5, the pulse lengths of laser signals LASER1 and LASER2 are always iden-
tical.
Clock frequency:
- in RTC
®
5 mode: fixed clock frequency of 64 MHz
- for the RTC
®
4 and in RTC
®
4 compatibility mode: 1 MHz or 8 MHz
References set_laser_pulses_ctrl, set_laser_pulses, set_laser_mode, set_firstpulse_killer,
set_firstpulse_killer_list, set_standby, set_standby_list
Undelayed
Short
List Command
set_list_jump
Function Execution produces an unconditional jump to the specified address within the list buffer.
The next command there will be executed immediately without delay.
Call
set_list_jump( Pos )
Parameter
Pos
absolute jump address [0 (2
20
–1)] as an unsigned 32-bit value
Comments The set_list_jump command is synonymous with list_jump_pos – see the comments
there.
RTC
®
4
RTC
®
5 unchanged functionality (except for the extended range of values)
References list_jump_pos
Delayed Short
List Command
set_laser_timing