10 Commands And Functions
478
innovators for industry
Ctrl Command set_sky_writing_limit
Function defines the limit for Sky Writing switching in mode 3.
Call
set_sky_writing_limit( Limit )
Parameters
Limit
Desired limit as a 64-bit IEEE floating point value;
allowed range: [–1.0 +1.0]; out-of-range values will be edge-clipped.
Comments For command usage, see "Sky Writing", page 113.
Limit
is the cosine of the angular limit (for angular change between consecutive vectors
or arcs within a polygonal traversal) for which a Sky Writing motion should be
performed.
The initialized value (after program start) is
Limit
= 0 (angular limit = 90°).
RTC
®
4
RTC
®
5 new command
Version info Available beginning with version DLL 531, OUT 532
References set_sky_writing_limit_list
Undelayed
Short
List Command
set_sky_writing_limit_list
Function identical with set_sky_writing_limit (see above), but a list command
Call
set_sky_writing_limit_list( Limit )
Parameters
Limit
See set_sky_writing_limit.
Comments See set_sky_writing_limit.
RTC
®
4
RTC
®
5 new command
Version info Available beginning with version DLL 531, OUT 532
References set_sky_writing_limit
Normal
List Command
set_sky_writing_list
Function identical with set_sky_writing (see above), but a list command
Call
set_sky_writing_list( Timelag, LaserOnShift )
Parameters
Timelag
See set_sky_writing_para.
LaserOnShift
See set_sky_writing_para.
Comments See set_sky_writing, set_sky_writing_para and set_sky_writing_para_list.
RTC
®
4
RTC
®
5 new command
References set_sky_writing, set_sky_writing_para, set_sky_writing_para_list.