10 Commands And Functions
477
Normal
List Command
set_serial_step_list
Function sets the starting serial number and the increment size for the serial-number-set most
recently selected via select_serial_set_list (or for serial-number-set 0 after
load_program_file).
Call
set_serial_step_list( No, Step )
Parameters
No
Serial number as an unsigned 32-bit value; allowed range: [0 … (2
32
–1)]
Step
Increment size as an unsigned 32-bit value;
allowed range: [0 … 9999]; only the last 4 decimal digits are used.
Comments • During initialization, the starting serial number (for mark_serial and mark_serial_abs)
is set to 0 and the increment size set to 1.
•If mark_serial or mark_serial_abs was called with Mode M
2
= 1 (i.e. automatic serial-
number incrementing was deactivated), then the increment size setting will have no
effect.
•If
Step
= 0, then incrementing will not occur, except in the case of markless marking
(see mark_serial or mark_serial_abs:
digits
= 0), which always increments serial
numbers by 1.
• For command usage, see chapter 7.5.2 "Marking Serial Numbers", page 150.
RTC
®
4
RTC
®
5 new command
Version info Available beginning with version DLL 537, OUT 537
References set_serial_step, select_serial_set_list, get_list_serial, mark_serial, mark_serial_abs
Ctrl Command set_sky_writing
Function activates or deactivates Sky Writing mode and sets the corresponding parameters
Call
set_sky_writing( Timelag, LaserOnShift )
Parameters
Timelag
See set_sky_writing_para.
LaserOnShift
See set_sky_writing_para.
Comments • The command is identical to set_sky_writing_para
(
Timelag
,
LaserOnShift
,
Nprev
,
Npost
)
with
Nprev
= approx. (0.15 ·
Timelag
) and
Npost
= approx. (0.1 ·
Timelag
).
• Also see information about set_sky_writing_para and "Sky Writing", page 113.