RTC
®
5 PC Interface Board
Rev. 1.9 e
14 Technical Specifications of the RTC
®
5 PC Interface Board
570
14 Technical Specifications of the RTC
®
5 PC Interface Board
System Requirements
IBM-compatible PC with PCI bus interface
Operating system Microsoft (32 bit or 64 bit)
WINDOWS 8,
WINDOWS 7,
WINDOWS Vista and
WINDOWS XP (SP2 or
higher)
Dimensions
Length 160 mm
Height 100 mm
Interface to Scan System
Connectors
• optionally
activated:
Primary scan head
connector SCAN HEAD
(9-pin D-SUB, female)
Secondary scan head
connector 2. SCAN HEAD
(10-pin socket connector)
Signals
• optional:
SL2-100 protocol
XY2-100 protocol via
XY2-100 converter
Scan System Control
Number of list buffer
areas
up to 3 (configurable)
Capacity of list buffer 1000000 commands
Position update period
(microstep period)
10 µs
Maximum range for
the image field
coordinates
– 524288 to +524287
(20-bit signed)
Virtual image field
(e.g. for Processing-
on-the-fly)
– 8388608 to +8388607
(24-bit signed)
Interfaces for the Laser and for Peripheral
Equipment
• LASER Connector
Connector 15-pin D-SUB connector,
female
Laser signals
•TTL level
• Max. current load
• Reference
LASER1, LASER2,
LASERON
5 V, active-high or active-
low (programmable)
20 mA
GND (alternatively: GND2
with optional galvanical
decoupling)
Analog outputs
•Output voltage
range
•Resolution
• Max. current load
• Reference
ANALOG OUT1,
ANALOG OUT2
0V…10V
12 Bit
5mA
GND
Digital input
•LOW level
•HIGH level
• Max. input voltage
range
• Input resistance
(pull-up)
• Reference
2Bits
<0.6V
>2.3V
–0.5 V … +5.5 V
> 4.7 k
GND
Digital output
•LOW level
•HIGH level
• Max. current load
• Reference
2 bits, buffered
< 0.55 V
> 3.8 V
20 mA
GND