RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
303
innovators for industry
Undelayed
Short
List Command
if_not_fly_y_overflow
Function Conditional command execution for Processing-on-the-fly applications: This command
immediately executes the directly subsequent list command if the condition in accordance
with
Mode
for the Y axis was not fulfilled. Otherwise, the next list command is skipped over.
Call
if_not_fly_y_overflow( Mode )
Parameters
Mode
To-be-evaluated condition as a signed 32-bit value:
= 0: Some kind of boundary exceedance occurred
(error bit#6 = 1 or error bit#7 = 1).
> 0: An overflow occurred (error bit#7 = 1).
< 0: An underflow occurred (error bit#6 = 1).
Comments For command usage, see page 190.
The error bits queried in accordance with
Mode
(error bit#6 and/or error bit#7) will be
reset.
RTC
®
4
RTC
®
5 new command
Version info Available beginning with version DLL 525, OUT 527
References get_marking_info, set_fly_limits, clear_fly_overflow, if_fly_y_overflow
Undelayed
Short
List Command
if_not_fly_z_overflow
Function Conditional command execution for Processing-on-the-fly applications: This command
immediately executes the directly subsequent list command if the condition in accordance
with
Mode
for the Z axis was not fulfilled. Otherwise, the next list command is skipped over.
Call
if_not_fly_z_overflow( Mode )
Parameters
Mode
To-be-evaluated condition as a signed 32-bit value:
= 0: Some kind of boundary exceedance occurred
(error bit#24 = 1 or error bit#25 = 1).
> 0: An overflow occurred (error bit#25 = 1).
< 0: An underflow occurred (error bit#24 = 1).
Comments For command usage, also see "Monitoring Processing-on-the-fly Corrections", page 190.
The error bits queried in accordance with
Mode
(error bit#24 and/or error bit#25) will
be reset.