RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
369
innovators for industry
Normal
List Command
micro_vector_rel_3d
Function moves the output point (of the laser focus) via a hard jump (without microvectorization)
directly from the current position to the specified position (relative coordinate values)
within a three-dimensional process volume.
Restriction If the 3D option is not enabled or no 3D correction table has been assigned (see
select_cor_table), then the command will have the same effect as micro_vector_rel.
Call
micro_vector_rel_3d( dX, dY, dZ, LasOn, LasOff )
Parameters
dX,dY,dZ
relative coordinates of the micro vector end point in bits as signed 32-bit
values; allowed range:
•for
X
and
Y
: [–8388608 8388607] (out-of-range values will be edge-
clipped). The complete value range [–8388608 8388607] is only usable
as a virtual image field e.g. for (enabled) Processing-on-the-fly applica-
tions. The current coordinates will be clipped to [–524288 524287] (real
image field size) during runtime directly prior to use of the correction table.
•for
Z
: [–32768 32767] (out-of-range values will be edge-clipped).
LasOn,
LasOff
LaserOn delay and LaserOff delay (see micro_vector_abs_3d)
Comments The coordinates for the vector’s end point are to be supplied as relative coordinates
with respect to the current position. Otherwise, the command is identical to
micro_vector_abs_3d (see the comments there).
The microvector always executes as a hard jump.
RTC
®
4
RTC
®
5 new command
RTC
®
4 compatibility mode: see micro_vector_abs_3d.
Version info Available with version DLL 536, OUT 536
References micro_vector_abs_3d, micro_vector_rel