10 Commands And Functions
402
innovators for industry
Variable
List Command
select_cor_table_list
Function similar to select_cor_table (see above), but a list command
Call
select_cor_table_list( HeadA, HeadB )
Parameters
HeadA
= 0: turns off the signals for scan head A (primary scan head connector)
= 1…4: assigns correction table number
HeadA
to scan head A
(as an unsigned 32-bit value)
HeadB
= 0: turns off the signals for scan head B (secondary scan head connector)
= 1…4: assigns correction table number
HeadB
to scan head B
(activation required)
(as an unsigned 32-bit value)
Comments See select_cor_table (page 400).
Even though select_cor_table_list is a short list command, execution of the directly
following list command will be delayed by a few clock cycles due to the intermediate
jump to the corrected galvanometer position. The extent of this delay depends on the
assigned correction table’s content for the current galvanometer position (e.g. (0|0)
after load_program_file); but it is at least 10 µs, even if the correction table doesn’t
specify a correction.
RTC
®
4
RTC
®
5new command
Version info Last change (with version DLL 533, OUT 534): the parameter’s value range has been
increased to [0…4] (load_correction_file lets you load up to 4 correction files)