10 Commands And Functions
489
innovators for industry
Delayed Short
List Command
set_standby_list
Function same as set_standby (see above), but a list command
Call
set_standby_list( HalfPeriod, PulseLength )
Parameters
HalfPeriod
half of the stand-by output period as an unsigned 32-bit value.
1 bit equals 1/64 µs. Allowed range: [0 … +(2
32
1)]
PulseLength
Pulse length of the stand-by pulses as an unsigned 32-bit value.
1 bit equals 1/64 µs. Allowed range: [0 (2
32
1)]
RTC
®
4
RTC
®
5as set_standby
Ctrl Command set_start_list
Function opens the list buffer for writing of list commands and sets the input pointer to the start of
the desired list (“List 1” or “List 2”). The next list command will be stored at this address
and all further list commands at the subsequent addresses in the selected list.
Call
set_start_list( ListNo )
Parameter
ListNo
Number of the list in which the input pointer should be set, as an unsigned
32-bit value
permissible values: [uneven: “List 1“, even: “List 2“]
Comments The set_start_list command is synonymous with set_start_list_pos for
Pos
= 0.
Alternatively, the commands set_start_list_1 and set_start_list_2 (with no parameter)
can be used.
RTC
®
4
RTC
®
5 unchanged functionality
References execute_list, read_status, set_start_list_pos
Ctrl Command set_start_list_1
Function see set_start_list
Call
set_start_list_1()
RTC
®
4
RTC
®
5 unchanged functionality
References set_start_list
Ctrl Command set_start_list_2
Function see set_start_list
Call
set_start_list_2()
RTC
®
4
RTC
®
5 unchanged functionality
References set_start_list