EasyManua.ls Logo

Scanlab RTC 5 PC Interface Board - set_free_variable; set_free_variable_list

Scanlab RTC 5 PC Interface Board
622 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
433
innovators for industry
Ctrl Command set_free_variable
Function sets a free variable to the desired value.
Call
set_free_variable( No, Value )
Parameters
No
Number of the free variable to be set as an unsigned 32-bit value.
Allowed range: [0 3]
Only the two least significant bits are evaluated.
Value
Desired variable value as an unsigned 32-bit value.
Allowed range: [0 (2
32
1)]
Comments See chapter 6.9.1 "Free Variables", page 92.
RTC
®
4
RTC
®
5new command
Version info Available beginning with version DLL 531, OUT 532
References set_free_variable_list, get_free_variable, set_trigger
Undelayed
Short
List Command
set_free_variable_list
Function same as set_free_variable (see above), but a list command
Call
set_free_variable_list( No, Value )
Parameters
No
See set_free_variable.
Value
See set_free_variable.
Comments See set_free_variable.
RTC
®
4
RTC
®
5new command
Version info Available beginning with version DLL 531, OUT 532
References set_free_variable

Table of Contents