10 Commands And Functions
348
innovators for industry
RTC
®
4
RTC
®
5 unchanged functionality (except for changed value ranges and error codes)
If the correct calibration factors are used (see page 172), then the same ABC coefficients
can be used on the same 3-axis scan system with the RTC
®
4 and RTC
®
5 boards.
Version info Last change with version DLL 516
References get_z_distance
Normal
List Command
long_delay
Function pauses further processing of the list for the specified time
Call
long_delay( Delay )
Parameter
Delay
delay time in bits as an unsigned 32-bit value.
1bit equals 10µs. Allowed range: 0 delay (2
32
–1).
Comments This command (if applicable) switches off the “laser active” laser control signals after a
LaserOff delay, waits for a possible scanner delay and pauses further processing of the
list for the specified time.
This command should always be called after changing the lamp current of a YAG laser
to obtain a constant laser power.
•The command list_nop corresponds to
long_delay( 1 )
.
RTC
®
4
RTC
®
5 unchanged functionality (except for the increased range of values)