10 Commands And Functions
480
innovators for industry
Normal
List Command
set_sky_writing_mode_list
Function identical with set_sky_writing_mode (see above), but a list command
Call
set_sky_writing_mode_list( Mode )
Parameters
Mode
See set_sky_writing_mode.
Comments Unlike set_sky_writing_mode, the command set_sky_writing_mode_list lets you
activate or deactivate Sky Writing mode 2 or 3 (switching to or from
Mode
= 2 or 3) even
within a list. Here, a temporary switch to Sky Writing mode 1 occurs.
Deactivation of Sky Writing mode 1 via set_sky_writing_mode_list (switching from
Mode
= 1 to 0) results in the addition of a mark delay defined prior to activation of Sky
Writing – provided that no other delay is in effect (e.g. a jump delay).
RTC
®
4
RTC
®
5 new command
Version info Available beginning with version DLL 527, OUT 529, RBF 519
Last change with version DLL 531, OUT 532: mode 3
References set_sky_writing_mode