List Command
apply_mcbsp_list
Function same as apply_mcbsp (see above), but a list command
Call
apply_mcbsp_list( HeadNo, at_once )
Parameters
HeadNo
See apply_mcbsp.
at_once
This parameter (unsigned 32-bit value) determines when the defined
transformation becomes effective:
= 0: The transformation settings are only collected and intermediately
stored, but the transformation is not processed as long as this is not
activated via another coordinate transformation (e.g. via a list
command with
at_once
= 1 or a corresponding control command).
= 1: The transformation is immediately calculated (including all
transformation settings that were collected until then) and processed
prior to the next list command.
= 2: The transformation settings are only collected and intermediately
stored (as with
at_once
= 0). However, The transformation is
immediately calculated (including all transformation settings that
were collected and intermediately stored until then) and applied to
the current position when the next jump_abs, jump_rel, goto_xy or
goto_xyz command is executed.
> 2: See
at_once
=2
Comments See apply_mcbsp.
RTC
®
4
RTC
®
5new command
Version info Available beginning with version DLL 524, OUT 526
References apply_mcbsp