RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
529
innovators for industry
Version info Available beginning with version DLL 515, OUT 514, RBF 512
Updated with version DLL 518, OUT 517, RBF 515: enhanced master/slave synchroniza-
tion (see page 611); we recommend only using the updated version of the command.
Updated with version DLL 523, OUT 524: also triggers matching of short-command
counts when necessary (see page 84).
References get_master_slave, get_sync_status
Normal
List Command
time_fix
Function stores the current time and date of the RTC
®
clock/calender in a buffer for use with
mark_date and mark_time.
Call
time_fix()
Comments The command time_fix is synonymous with time_fix_f_off with
FirstDay
= 0 and
Offset
= 0 (see comments there).
RTC
®
4
RTC
®
5 unchanged
(the command was previously only available for the RTC
®
SCANalone Board, i.e. the
standalone version of the RTC
®
4 board)
Version info Last change with version OUT 517
References time_fix_f, time_fix_f_off
Normal
List Command
time_fix_f
Function stores the current time and date of the RTC
®
clock/calender in a buffer for use with
mark_date and mark_time.
Call
time_fix_f( FirstDay )
Parameter
FirstDay
See time_fix_f_off.
Comments The command time_fix_f is synonymous with time_fix_f_off with
Offset
= 0 (see
comments there).
RTC
®
4
RTC
®
5new command
Version info Last change with version OUT 517
References time_fix_f, time_fix_f_off, time_update, mark_time, mark_date
Ctrl Command sync_slaves