RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
487
innovators for industry
Variable
List Command
set_softstart_mode_list
Function same as set_softstart_mode (see above), but a list command
Call
set_softstart_mode_list( Mode, Number, Delay )
Parameters See set_softstart_mode.
Comments set_softstart_mode_list switches off the “laser active” laser control signals by
executing list_nop and waits until the LaserOff delay has expired.
Otherwise this command is identical to the control command set_softstart_mode (also
see the comments there).
RTC
®
4
RTC
®
5new command
Version info Available as of version DLL 536, OUT 536
References set_softstart_mode, set_softstart_level, set_softstart_level_list