EasyManua.ls Logo

Scanlab RTC 5 PC Interface Board - timed_mark_rel

Scanlab RTC 5 PC Interface Board
622 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RTC
®
5 PC Interface Board
Rev. 1.9 e
10 Commands And Functions
539
innovators for industry
Normal
List Command
timed_mark_rel
Function moves the laser focus for the specified marking duration along a 2D vector from the
current position to the specified position (relative coordinate values) within a two-
dimensional image field.
Call
timed_mark_rel( dX, dY, T )
Parameters
dX, dY
relative coordinates of the mark vector end point in bits as signed 32-bit
values; allowed range: [–8388608 8388607] (out-of-range values will be
edge-clipped). The complete value range [–8388608 8388607] is only
usable as a virtual image field e.g. for (enabled) Processing-on-the-fly
applications. The current coordinates will be clipped to [–524288 524287]
(real image field size) during runtime directly prior to use of the correction
table.
T
duration of the complete mark vector in microseconds (as a 64-bit IEEE
floating point value); allowed range: [0 167772160]; the parameter will be
rounded to an integer-multiple of 10; out-of-range values will be clipped.
If
T
< 5, then timed_mark_rel behaves like mark_rel).
Comments The coordinates for the mark vector’s end point are to be supplied as relative coordi-
nates with respect to the current position. Otherwise, the command is identical to
timed_mark_abs (see the comments there, exception:
T
< 5, see above).
RTC
®
4
RTC
®
5 unchanged functionality (except for the extended range of values, and
T
< 5 does not
execute timed_mark_rel, but instead mark_rel).
In RTC
®
4 compatibility mode, the RTC
®
5 multiplies the specified coordinate values by 16
(the permissible range of values is correspondingly reduced).
References timed_mark_abs, mark_rel, timed_mark_rel_3d