10 Commands And Functions
502
innovators for industry
RTC
®
4
RTC
®
5 The RTC
®
4 only executed (elliptical) wobbel movements permanently referenced to the
coordinate system. For the RTC
®
5, the parameters
Transversal
and
Longitudinal
can be
used to define an ellipse-shaped movement (the frequency’s sign determines the direction
of rotation) that follows the current direction of movement.
The image field coordinates for the X and Y axes are specified as 20-bit values; in RTC
®
4
compatibility mode they are specified as 16-bit values (as with the RTC
®
4) and the RTC
®
5
multiplies the specified value for the amplitudes
Longitudinal
and
Transversal
by 16 (the
permissible range of values is correspondingly reduced to [1 8191]).
References set_mark_speed, set_wobbel_mode