EasyManua.ls Logo

Sensopart Visor - Auto Operating Distance (ASCII) Response String from Sensor

Sensopart Visor
263 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VISOR
®
Communications manual
Auto operating distance (ASCII) response string from sensor
Byte no. Content Meaning
1 A
Auto Focus2 F
3 C
4
P
F
P successful (Pass)
F Fail
5 - 7 X Error codes (Page 88)
8 - 10 X Number of operating distances
NOTE:
The following byte sequence is repeated for each operating
distance. The byte numbers shift accordingly.
11 - 18 X Operating distance
19 - 26 X Score
Example: AFCP00000200000095000000900009300000089000
Additional information:
Accepted in run mode: Yes
Accepted in config mode: No
Accepted when Ready is low: Yes
Status of Ready signal during processing: No change
Supported interfaces:
Telegrams: Availability and supported
interfaces (Page 85)
End of telegram: Max. 4 bytes (optional)
06814859 - 1/24/2019-00 Page 102 EN