EasyManua.ls Logo

Sensopart Visor - Read ROI (BINARY)

Sensopart Visor
263 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VISOR
®
Communications manual
Read ROI (BINARY)
Telegrams: Availability and supported interfaces (Page 85)
Overview telegrams (Page 81)
Read ROI (binary) request string to sensor
Byte no. Data type Content Meaning
1 - 4 Unsigned Int 0x07 Telegram length
5
Unsigned
Char
0x12 Get ROI
6
Unsigned
Char
0xXX Detector no.
7
Unsigned
Char
0xXX
ROI Index
00 = Yellow ROI
01 = Teach
02 = Position control
Read ROI (binary) response string from sensor
Byte no. Data type Content Meaning
1 - 4 Unsigned Int 0xXX Telegram length
5
Unsigned
Char
0x12 Get ROI
6 - 7
Unsigned
Short
0xXX Error codes (Page 88)
8 - 11 Unsigned Int 0xXX ROI info length in bytes from Byte 8
12
Unsigned
Char
0xXX Detector no.
13
Unsigned
Char
0x00
ROI Index
00 = Yellow ROI
01 = Teach
02 = Position control
14
Unsigned
Char
0xXX
ROI shape
01= Circle
06814859 - 1/24/2019-00 Page 216 EN