VISOR
®
Communications manual
11.1.5 Serial communication BINARY
Reset statistic (BINARY)
Telegrams: Availability and supported interfaces (Page 85)
Overview telegrams (Page 81)
Reset statistics (binary) request string to sensor
Byte no. Data type Content Meaning
1 - 4 Unsigned Int 0x05 Telegram length
5
Unsigned
Char
0x04 Reset Statistics
Reset statistics (binary) response string from sensor
Byte no. Data type Content Meaning
1 - 4 Unsigned Int 0x07 Telegram length
5
Unsigned
Char
0x04 Reset Statistics
6 - 7
Unsigned
Short
0xXX Error codes (Page 88)
Additional information:
Accepted in run mode: Yes
Accepted in config mode: No
Accepted when Ready is low: Yes
Status of Ready signal during
processing:
Low
Supported interfaces:
Telegrams: Availability and supported interfaces
(Page 85)