VISOR
®
Communications manual
Read shutter speed (ASCII)
Telegrams: Availability and supported interfaces (Page 85)
Overview telegrams (Page 81)
Read shutter speed value (ASCII) request string to sensor
Byte no. Content Meaning
1 G
Get Shutter Speed (from active job)2 S
3 H
Example: GSH
Read shutter speed value (ASCII) response string from sensor
Byte no. Content Meaning
1 G
Get Shutter Speed2 S
3 H
4
P
F
P successful (Pass)
F Fail
5 X Shutter speed value, length
6 ... n X Shutter speed value
Example Run Mode:
Example Configuration
Mode:
GSHP41200
GSHF0
Additional information:
Accepted in run mode: Yes
Accepted in config mode: No
Accepted when Ready is low: Yes
Status of Ready signal during processing: No change
Supported interfaces: