VISOR
®
Communications manual
Value Description
Length
Binary
[Byte]
Data type
Available
for
Score [%] 4
Signed
integer
All detectors
Overall
result
Boolean detector result 1 Boolean All detectors
Execution
time
Execution time of individual detector in
[msec].
4
Signed
integer
All detectors
Position
Value Description
Length
Binary
[Byte]
Data
type
Available
for
Pos. X
X coordinate for the found position,
1/1000 [user unit]
4
Signed
integer
Pos. Y
Y coordinate for the found position,
1/1000 [user unit]
4
Signed
integer
Delta pos.
X
X position delta between the taught object and
the found object,
1/1000 [user unit]
4
Signed
integer
06814859 - 1/24/2019-00 Page 252 EN