VISOR
®
Communications manual
Calibration: Read parameter (ASCII)
Telegrams: Availability and supported interfaces (Page 85)
Overview telegrams (Page 81)
Calibration: Read parameter (ASCII) request string to sensor
Byte no. Content Meaning
1 C
Calibration: Get Parameter2 G
3 P
4 1 Request version
5 - 7 X Parameter number (Page 156)
Example: CGP1001
Calibration: Read parameter (ASCII) response string from sensor
Byte no. Content Meaning
1 C
Calibration: Get Parameter2 G
3 P
4
P
F
P successful (Pass)
F Fail
5 - 7 X Error codes (Page 88)
8 - 10 X Parameter number (Page 156)
11 - 18 X Length of the following data
19 ... n X Parameter values, depending on the selected parameter
Example: CGPP000001000000011
Additional information:
Accepted in run mode: Yes
Accepted in config mode: No
Page 155 EN 06814859 - 1/24/2019-00