VISOR
®
Communications manual
Save job permanently (BINARY)
Telegrams: Availability and supported interfaces (Page 85)
Overview telegrams (Page 81)
Save job permanently (binary) request string to sensor
Byte no. Data type Content Meaning
1 - 4 Unsigned Int 0x5 Telegram length
5
Unsigned
Char
0xD Save job permanently
Save job permanently (binary) response string from sensor
Byte no. Data type Content Meaning
1 - 4 Unsigned Int 0x0B Telegram length
5
Unsigned
Char
0x31 Save job permanently
6 - 7
Unsigned
Short
0xXX Error codes (Page 88)
Additional information:
Accepted in run mode: Yes
Accepted in config mode: No
Accepted when Ready is low: Yes
Status of Ready signal during processing: Low
Supported interfaces:
Telegrams: Availability and supported interfaces
(Page 85)
Page 225 EN 06814859 - 1/24/2019-00