VISOR
®
Communications manual
Job change (ASCII)
Telegrams: Availability and supported interfaces (Page 85)
Overview telegrams (Page 81)
Job change (ASCII) request string to sensor
Byte no. Content Meaning
1 C
Change Job2 J
3 B
4 - 6 X Job number
Example: CJB005
Job change (ASCII) response string from sensor
Byte no. Content Meaning
1 C
Change Job2 J
3 B
4
P
F
P successful (Pass)
F Fail
5
T
F
Triggered
Freerun
6 - 8 X Job number
Example 1:
Example 2:
CJBPT005
CJBFF005
Additional information:
Accepted in run mode: Yes
Accepted in config mode: No
Accepted when Ready is low: Yes