EasyManua.ls Logo

Sensopart Visor - Read Trigger Delay (ASCII)

Sensopart Visor
263 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VISOR
®
Communications manual
Read trigger delay (ASCII)
Telegrams: Availability and supported interfaces (Page 85)
Overview telegrams (Page 81)
Read trigger delay V1 (ASCII) request string to sensor
Byte no. Content Meaning
1 G
Get Trigger Delay2 T
3 D
4 1 Request version
Example: GTD1
Read trigger delay V1 (ASCII) response string from sensor
Byte no. Content Meaning
1 G
Get Trigger Delay2 T
3 D
4
P
F
P successful (Pass)
F Fail
5 - 7 X Error code
8 - 15 X
Trigger delay
in msec (max. 3000 msec)
in encoder steps (max. 65535 steps)
Example: GTDP00000001000
Additional information:
Accepted in run mode: Yes
Accepted in config mode: No
Accepted when Ready is low: Yes
Status of Ready signal during
processing:
No change
06814859 - 1/24/2019-00 Page 136 EN