VISOR
®
Communications manual
Save job permanently (ASCII)
Telegrams: Availability and supported interfaces (Page 85)
Overview telegrams (Page 81)
Save job permanently (ASCII) request string to sensor
Byte no. Content Meaning
1 S
Store Job Permanently2 J
3 P
Example: SJP
Save job permanently (ASCII) response string from sensor
Byte no. Content Meaning
1 S
Store Job Permanently2 J
3 P
4
P
F
P successful (Pass)
F Fail
Example: SJPP
Additional information:
Accepted in run mode: Yes
Accepted in config mode: No
Accepted when Ready is low: Yes
Status of Ready signal during
processing:
Low
Supported interfaces:
Telegrams: Availability and supported interfaces
(Page 85)
End of telegram: Max. 4 bytes (optional)