EasyManua.ls Logo

Sensopart Visor - Update Firmware (ASCII)

Sensopart Visor
263 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VISOR
®
Communications manual
Update firmware (ASCII)
Telegrams: Availability and supported interfaces (Page 85)
Overview telegrams (Page 81)
Update firmware (ASCII) request string to sensor
Byte no. Content Meaning
1 U
Update Firmware2 F
3 W
4 1 Request version
Example: UFW1
Update firmware (ASCII) response string from sensor
Byte no. Content Meaning
1 U
Update Firmware2 F
3 W
4
P
F
P Pass
F Fail
5 - 7 X Error codes (Page 88)
Example: UFWP000
Additional information:
Accepted in run mode: Yes
Accepted in config mode: No
Accepted when Ready is low: Yes
Supported interfaces:
Telegrams: Availability and supported interfaces (Page
85)
End of telegram: Max. 4 bytes (optional)
Page 167 EN 06814859 - 1/24/2019-00

Table of Contents