VISOR
®
Communications manual
Job change permanent (ASCII)
Telegrams: Availability and supported interfaces (Page 85)
Overview telegrams (Page 81)
Job change, permanent (ASCII) request string to sensor
Byte no. Content Meaning
1 C
Change Job Permanent2 J
3 P
4 - 6 X Job number
Example: CJP005
Job change, permanent (ASCII) response string from sensor
Byte no. Content Meaning
1 C
Change Job Permanent2 J
3 P
4
P
F
P successful (Pass)
F Fail
5
T
F
Triggered
Freerun
6 - 8 X Job number
Example 1:
Example 2:
CJPPT005
CJPFF005
Additional information:
Accepted in run mode: Yes
Accepted in config mode: No
Accepted when Ready is low: Yes
Status of Ready signal during
Low
Page 97 EN 06814859 - 1/24/2019-00